High-end EDXRF spectrometer
C - AM的元素分析
The S2 PUMA Series 2 with a single-position manual loading enjoys the same technical benefits as the S2 PUMA Series 2 XY Autochanger and S2 PUMA Series 2 Carousel.
It delivers a simple sample handling mechanism for low sample volumes and can be fitted with the fast HighSense™ detectors and the ergonomic TouchControl™.
没有触摸屏,它可以远程控制,也可以通过带有仪器控制软件频谱的外部PC来控制。
High Performance for Small Sample Batches
Easy Operation and Shortest Training Time
Measure any sample in minutes: Solid, fused bead, pressed pellet, loose powder, liquid, bulk – simply load sample batches using the EasyLoadTM tray or place your bulk sample directly into the chamber. The S2 PUMA Series 2 offers the largest sample chamber with dimensions of 450 x 420 x 100 mm. Its carousel tray can hold mixed batches with up to 12 samples of 32, 40, or 51.5 mm in diameter or up to 18 samples of 40 mm in diameter.
The S2 PUMA Series 2 Carousel is the all-rounder among the benchtop EDXRF analyzers when it comes to sample versatility.
Any Sample Type
Small-Spot Analysis
SMART.QUANT FP
The S2 PUMA Series 2 with mapping-stage makes multi-spot quality monitoring an easy task. It lets you quantify the elemental composition of your sample or even the thickness of a coating with high accuracy and spatial resolution (down to 1 mm). The linear motion-drive positions the sample precisely and reproducible. The actual position can be recorded with an integrated HD camera.
映射阶段将S2 PUMA系列2的应用范围扩展到需要空间分辨率的半导体和涂层中。
可用于各种样本量的插入物,直径从40毫米到152毫米不等。可根据要求提供自定义插入物。
Key Benefits
WDXRF sample handling on a benchtop EDXRF unit – the S2 PUMA Series 2 XY Autochanger is equipped with a 20-position sample tray and sample grabber with liquid sample detection.
仪器是理想的更大的样本容量at a production line, where the S2 PUMA Series 2 can be operated with the integrated user-friendly TouchControl™ touchscreen.
样品处理
Power and Speed
Instrument Protection
The only benchtop EDXRF which can professionally be integrated into fully automated laboratories. The S2 PUMA Series 2 Automation delivers results on elemental analysis 24/7. The instrument can be connected either via conveyer belt or robot arm link-up to the preparation module. The sample feed interface is at the instrument’s backside, so that the XY Autochanger capabilities remain fully available. Buffer positions inside the instrument in addition to the EasyLoadTMXY tray ensure smooth handling of automated and out-of-line samples at any time.
The HD camera can be used for sample verification: Samples in automation rings run overnight are often not available any more in the morning when staff returns. As a helpful validation tool, the pictures taken automatically by the camera can help to identify e.g. a failed sample surface and thus provide valuable information to clarify suspicious analysis results.
The LIMS-compatible instrument can communicate through Bruker’s dedicated AXSCOM software package with process control units and ensures full integration into existing or new laboratory environments.
24/7 Production Control
快速地- Powerful - Accurate
The HighSense detectors are equipped with a fast 8k multi-channel analyzer (MCA) for high count rates and excellent energy resolution. The newHighSenseTMXPdetector is the latest addition to the HighSense Silicon Drift Detector (SDD) generation of the S2 PUMA Series 2.
多亏了超高的传输石墨烯窗口,HighSense XP对EDXRF可检测到的所有元素都提供了一流的灵敏度。结合新的最先进的探测器分析feature, the HighSense XP sets new standards for benchtop EDXRF instruments.
HighSenseTMturns Power into Speed
The direct excitation beam path of the S2 PUMA Series 2 makes full use of the high-power 50 Watt X-ray tube. Optimal excitation of all elements in the sample is guaranteed with up to 50 kV voltage, up to 2 mA current, closely-coupled beam optics, and a 10-position primary beam filter-changer. In combination with the HighSenseTMdetector technology this pays back immediately: Better detection limits, higher precision, shorter measurement times!
SampleCare™ is a unique multi-layer system to protect vital instrument components from contamination. It protects the X-ray tube and the detector from spillage of liquid samples, from particles of solid samples, and from dust. The detector head is protected by DustShield™, an easy-to-replace cap with a high-transmission film. The tube is protected by the filter wheel. A sample type detection (XY Autochanger/Automation only) prevents the analysis of liquid samples, while the system is under vacuum.
SampleCare™表示高正常运行时间和易于维护!
TouchControl™ is the S2 PUMA Series 2’s integrated touch screen for easiest instrument operation. The TouchControl user interface enables users with only minimal training to run routine measurements. The tiles on main screen make important functions easily available while restricting access to instrument configuration and calibrations.
SPECTRA.ELEMENTS is the powerful and intuitive spectrometer software for the S2 POLAR, the S2 PUMA Series 2 and the S6 JAGUAR. It provides a wide range of tools for full spectrometer control and was developed with the user in mind: Its integrated design avoids floating windows and its tab-based layout allows quick access to all functionality.
Optional Add-Ons
SMART-QUANT FP is offered as fully integrated component of the S2 PUMA Series 2’s instrument software package SPECTRA.ELEMENTS, delivering reliable elemental compositions for solid, fused, pressed, powdered or liquid material, even with minimal user input.
智能定量FP设置为以完整的基本参数(FP)模式工作 - 这意味着无需校准!
Specification |
Benefit |
|
Element Range |
Sodium to americium (Na – Am) Carbon to americium (C – Am) with light element (LE) detector |
Covers most of the periodic table of elements |
Concentration Range |
From ppm to 100 % |
Measures major and trace elements in one sample |
X-ray Tube |
Pd or Ag anode; 50 W, max. 2 mA, max. 50 kV (30 kV available) |
High power combined with direct excitation and closely-couples beam optics for optimal analytical performance |
主梁过滤器 |
10-position automatic filter changer |
Optimized excitation for enhanced peak-to-background ratio. Protects the X-ray tube. |
Detector |
HighSense™ (Na – Am) HighSense™ LE (C – Am) |
Peltier cooled Silicon Drift Detector (no need for liquid nitrogen) protected DustShield™ Super-high count rates and excellent energy resolution. |
准直仪面具* |
1、3、8、12、18、23和28毫米(34毫米无面膜) |
For small spot analysis |
Sample Observation* |
Integrated HD video camera |
For exact sample positioning and documenting the measurement position on a sample |
Atmosphere Modes |
Air mode |
For heavier elements in all sample types |
真空模式* |
Best light element performance for stable samples and lowest cost of operation |
|
Helium mode*: |
For best light element analysis in volatile liquids such as fuels |
|
压力降低*的氦模式* |
For best light element performance with non-volatile liquid and loose powder samples and lowest helium consumption |
|
Nitrogen mode* |
Cost saving analysis of liquid samples |
|
TouchControl™* |
集成12.1英寸TFT触摸屏,可调,语言:英语,德语,法语,西班牙语,葡萄牙语,意大利语,俄语,中文和日语(其他要求) |
Easy and Failsafe operation (only minimal training required) |
Sample Types |
Loose powders, granules, solids, pressed pellets, fused beads, and liquids |
Analyze all sample types |
Sample Rotation* |
Spins all sample types and sizes |
For better measurement statistics with inhomogeneous samples |
Connectivity |
Built-in Ethernet port RJ45, 3x USB ports for mouse, keyboard, printer |
Easy to connect to your network |
Power Requirements |
100-240 V, 50/60 Hz, max. power consumption 600 VA |
Standard wall plug |
Quality & Safety |
DIN EN ISO 9001:2015,DIN EN ISO 14001:2015,2006/42/EC(CE认证的机械指令),2014/35/EC(电气设备),2014/30/EC(电磁兼容性),德国类型批准和Vollschutz根据BFS ROV,完全受辐射保护的系统;辐射<1μsv/h(H*),符合ICRP,IAEA,EURATOM |
|
*可选软件包 |
S2 PUMA Series 2 Single |
S2 PUMA Series 2 Carousel |
S2 PUMA Series 2 映射阶段 |
S2 PUMA Series 2 XY Autochanger |
S2 PUMA Series 2 自动化 |
Single position, 手动加载 |
EasyLoad™ Carousel sample 具有12或18个位置的托盘, removable to make room for large bulk samples |
Single position, 手动加载 |
EasyLoad™XY样品托盘 with 20 positions, removable; Grabber with automatic liquid sample detection |
EasyLoad™XY样品托盘具有20个位置,可移动; Grabber with automatic liquid sample detection; Interface to conveyor belt or robot arm link-up to sample preparation |
最多51.5毫米(2.03“)Ø; Liquid cups up to 50 ml |
Up to 51.5 mm Ø; Liquid cups up to 50 ml; Bulk samples up to 450 x 420 x 106 mm (width x depth x height) |
Up to 152 mm Ø; customized inserts available on request |
最多40毫米和 样品持有人的高度为38毫米,或51.5毫米作为样品环;液体杯最多20毫升 |
最多40毫米和38 mm height, or 51.5 mm Ø as sample ring; Liquid cups up to 20 ml |
67 x 71 x 37厘米(宽度深度x高度);87公斤 |
67 x 71 x 57厘米(宽度x深度x高);130公斤 |
67 x 71 x 57厘米(宽度x深度x高);132 kg |
67 x 71 x 61 cm (width x depth x height); 108 kg |
67 x 71 x 61 cm (width x depth x height); 110 kg |
We provide:
Check out oursupport websitefor:
Registration required.