加入Avance Track并保持您的MRI步入正轨

MRI Upgrade Program

Your research depends on the scientific advances that you make with your MRI instrument. You need an instrument that you can rely on to perform from day to day and well into the future. Take your instrument and your career to the next level by accessing cutting edge technologies. Ensure that your instrument is prepared for tomorrow's explorations. Most importantly, protect this highly valuable investment, which keeps you in the pole position when attractive interests arise. Maintain the viability and sustain the lifetime of your instrument with an upgrade of your Bruker or other manufacture instrument

Overview

The Right Upgrade Option for You

Joining the AVANCE Track is fast and simple. Existing Bruker customers will appreciate the streamlined procedure that expedites the upgrade process, while owners of MRI instruments from other vendors, such as Agilent, will value the individual attention to their particular needs.

对于其他供应商工具的所有者

对于其他供应商仪器的所有者,升级过程始于熟练的工程师的现场调查,他们将分析您的仪器当前配置。基于此信息,提供适合您工具的替代方案,并且您可以灵活地定义满足您科学和预算要求的大幅轨道的要素,因为潜在的选择是明确且透明的。指定配置后,服务工程师将实施转换,让您释放重新青春的仪器的功能。bob电竞官方网站

对于现有的布鲁克客户

现有的Bruker客户有可能通过使用Paravision 360软件升级到Avance Neo Electronics来维护最先进的技术。根据当前的仪器配置,划定了包含垫片,渐变和avance neo控制台升级等组件的单个升级选项。这使Avance Neo和Paravision 360的步骤以及对未来软件和硬件平台的相应转换是快速简便的过程。

强调

  • Maximize the performance of your instrument with the latest innovations of AVANCE NEO electronics andParavision 360software combined with optimalRF coil technology
  • 从最有效的工作流程中获利,从硬件设置开始,然后继续扫描到量化和数据管理
  • 通过确保获得进步发展,布鲁克的科学支持以及最重要的磁铁或完整的维护计划来确保您的工具为未来做好准备,以保护您最有价值的投资

1仅宠物/先生仪器
2Biospec 3T和PET/MR Inline Instruments

Technical Details

Increased Performance

An Unsurpassed Foundation

  • 最大性能梯度和垫片线圈与Avance Neo Electronics相结合,是您MRI仪器最强大的基础
  • High power shim amplifiers minimize artifacts in extremely shim sensitive sequences such as TrueFSIP and maximize quality in EPI
  • 领先的占空比性能高功率梯度,用于传导高度要求的序列,例如fMRI或第一次通过示踪剂吸收心脏
  • AVANCE NEO electronics allow gradient resolutions of 1 μs, and enable faster real time decisions than ever
  • UP 24传输和16个接收渠道的灵活配置可确保将来的应用可扩展性

Largest Preclinical Coil Portfolio

  • MRI CryoProbesfor SNR boost allowing for up to 6 times faster measurements and/or increased resolution
  • 专门的线圈,例如ASL和光遗传线圈
  • 并联发射线圈,最多8个通道
  • 分阶段阵列线圈,最多16个通道
  • Full range of classic room-temperature1H- and X-nuclei coils

Paravision 360的领先方法

  • 所有常见的自旋和梯度回声和光谱法
  • 所有标准,EPI和短回声成像方法,例如DTI-Spiral,ute和T1 EPI,用于扩散,灌注,fMRI,流量成像和松弛时间计
  • 独特的基于静脉的闪光和UTE方法,用于自卫无线心脏和呼吸成像
  • 脂肪化学移动伪影校正的稀有图像

礼貌:E。Barbier,L。Hirschler,J。Warnking,Grenoble神经科学研究所CASL Workflow套餐是与Emmanuel Barbier合作开发的。

简化和加速工作流程

Expediated Set-ups

  • Combinations of up to 4 RF coils simultaneously with active detuning
  • 完全自动硬件识别RF线圈,梯度和垫片线圈,用于软件控制的峰值功率限制

Efficient Scanning

  • 即将使用,体内,预优化协议和扫描程序可确保从第一天开始的最佳结果
  • ASL考试指南的最大数据一致性,这大大降低了用户偏见
  • 全心脏心脏评估比以往任何时候都更快
  • Paravision 360software's ease of use of a clinical software combined with
  • 布鲁克's open sequence programming framework

Expansive Reconstruction and Analysis

  • 与2D和3D图像共同注册的快速准确后处理,用于PET和/或MRI数据,融合图像,图像分析,配置文件,直方图以及ROI值的实时更新
  • 图像时间课程分析和多参数拟合,表面和音量渲染以及图像缝合
  • Professional and customizable data reports containing all scan parameters
  • Database with a hierarchical sorting function as well as a free text search
由于UTE的回声时间短和径向读数,因此自我门控的静脉内显示了小鼠在9.4 t中的流动和运动伪像减少,而不是IntragateFlash,即使加速获取细节:TE:0.4/1.5 ms(igute/igflash),tr tr tr tr tr:9毫秒,分辨率:(98×98)µm²,切片厚度:800 µm,电影帧:14

Avance Track -MRI升级手册免费下载

受保护的投资

An Instrument Prepared for the Future

  • 新时代的Avance Neo Electronics保证访问软件升级,包括未来方法,序列和模块
  • 访问宠物/先生仪器

连续支持

  • On-site and in-house trainings and webinars
  • 免费电子邮件和电话热线

有担保的投资

  • 实验室维护协议与质量程序
  • LabScape Comprehensive covering all technical issues up to and including full system replacement

MRI CryoProbe leads to average SNR increase of factor 2.8 at 9.4 T in mouse brain as opposed to room-temperature mouse brain coil Acquisition details: FLASH, resolution: (78 x 78 x 500) µm³, TR: 400 ms, TE: 3.8 ms, total time: 3 min. 24 s
Fat-water separation imaging in RARE leads to fat chemical shifted corrected images in mouse at 7 T Acquisition details: TE: 24 ms, TR: 350 ms, Resolution: (208 x 188) µm², Slice thickness: 1 mm, TA: > 1 m 7 s resp. trig. per slice

Application notes

Labscape

bob电竞官方网站服务和生命周期支持磁共振和临床前成像

力量的承诺为客户提供unparalleled help throughout the buying cycle, from initial inquiry to evaluation, installation, and the lifetime of the instrument is now characterized by the LabScape service concept.

LabScape Maintenance Agreements, On-Site On-Demand and Enhance Your Lab are designed to offer a new approach to maintenance and service for the modern laboratory